General Data:
| Indicator (25 ° C) model | SCD60-10mA | SCD60-20mA | SCD60-50mA |
| Rated current | ±10mA | ±20mA | ±50mA |
| Measuring range | 0~±20mA | 0~±40mA | 0~±100mA |
| Aperture | Φ17 | ||
| Output Interface | 485 interface, digital output (hexadecimal) | ||
| Baud rate | 9600bps | ||
| Operating Voltage | +12V (±5%) | ||
| Accuracy | 1% | ||
| Linearity | 1% | ||
| Refresh time | ≤60ms | ||
| Temperature drift characteristics | 500ppm/℃ | ||
| Isolation withstand voltage | ≤3000V DC | ||
| Current consumption | ≤11mA | ||
| Working temperature | -10℃~ +75℃ | ||
| Storage temperature | -25℃~ +85℃ | ||
Wiring table: